Category: Bradford White RG150T6N

Bradford White RG150T6N

RG150T6N – HONEYWELL COVER REMOVAL

Posted on December 4, 2021

Step 1. Rotate the knob of the gas control to the “OFF” position. Step 2. Turn off gas supply to the water heater. Step 3.…

Bradford White RG150T6N

RG150T6N – LINE PRESSURE

Posted on December 3, 2021

The gas valve is designed for a maximum line pressure of 14.0″ W.C., and a minimum line pressure based on the manifold pressure plus 1.0″…

Bradford White RG150T6N

RG150T6N – COMBINATION THERMOSTAT/GAS VALVE REPLACEMENT

Posted on December 3, 2021

Step 1. Rotate the knob of the gas valve to the “OFF” position. Step 2. Turn off gas supply to the water heater. Step 3.…

Bradford White RG150T6N

RG150T6N – ECO (ENERGY CUT OFF) TESTING

Posted on December 3, 2021

Step 1. Disconnect the thermocouple from the gas valve. Step 2. Using a multimeter capable of measuring ohms (or continuity), attach one lead using an…

Bradford White RG150T6N

RG150T6N – MAGNET ASSEMBLY TESTING (White Rodgers Mechanical Control)

Posted on December 3, 2021

Step 1. Following the lighting instruction label on the heater, proceed to light the pilot and allow to operate for three minutes. If the pilot…

Bradford White RG150T6N

RG150T6N – GAS VALVE TESTING AND REPLACEMENT (White Rodgers Mechanical)

Posted on December 3, 2021

GAS VALVE TESTING AND REPLACEMENT (White Rodgers Mechanical) The gas valve is a non-repairable device. If troubleshooting has determined a problem with the gas valve,…

Bradford White RG150T6N

RG150T6N – PIEZO IGNITER, ELECTRODE TESTING AND REPLACEMENT

Posted on December 3, 2021

With the pilot not in operation (no pilot flame) you can check the piezo and electrode circuit by viewing pilot through the sight glass located…

Bradford White RG150T6N

RG150T6N – PILOT/ELECTRODE ASSEMBLY INSPECTION, CLEANING, AND REPLACEMENT

Posted on December 3, 2021December 3, 2021

Step 1. Turn off gas supply to water heater. Rotate the knob of gas control/gas valve to the “OFF” position. Step 2. Remove the outer…

Bradford White RG150T6N

RG150T6N – OPEN CIRCUIT THERMOPILE TESTING (Honeywell & White Rodgers Electronic)

Posted on December 3, 2021

Step 1. Turn knob to pilot position and depress. Step 2. Continue pressing knob and remove the red (+) wire from resettable thermal door switch.…

Bradford White RG150T6N

RG150T6N – OPEN CIRCUIT THERMOCOUPLE TESTING (White Rodgers Mechanical)

Posted on December 3, 2021

Step 1. Disconnect the thermocouple from the combination thermostat/gas valve. Step 2. Using a multimeter capable of measuring millivolts, connect one alligator clip to the…

Posts navigation

Previous Page Page 1 Page 2 Page 3 Next Page

Pages

  • Contact Us

Recent Posts

  • How to Recalibrate a Thermostat
  • Solenoid Valves for Furnaces: A Basic Guide
  • Fuel Oil Burner Nozzles: What They Are and How They Work
  • Remote Bulb Temperature Control: A Basic Introduction
  • How to Clean Oil Burner Nozzle

Categories

  • A.O. Smith
  • Bradford White RG150T6N
  • Coal Firing
  • DIY
  • Gas and Oil Controls
  • Gas Burners
  • Honeywell Thermostat Manuals
  • Non-Condensing Models
  • Oil Burner
  • Steam and Hydronic Line
  • Thermostats and Humidistats
  • Troubleshooting
  • Valve
  • Wiring and Controls
© Copyright 2025 – Heater Service & Troubleshooting
Wisteria Theme by WPFriendship ⋅ Powered by WordPress

Terms and Conditions - Privacy Policy