Category: A.O. Smith

Non-Condensing Models

A.O. Smith 110-310-510 – ERROR CODE 651 [510 (T-D2)] ABNORMAL FLOW ADJUSTMENT VALVE

Posted on December 6, 2021

1) Turn off power supply. 2) Check that all wire connections are secure and free of burns. The flow adjustment valve is located behind the…

Non-Condensing Models

A.O. Smith 110-310-510 – ERROR CODE 611 [510 (T-D2)], FOUR FLASHES/61 [110 (T-KJR2), 310 (T-K4)] ABNORMAL FAN MOTOR

Posted on December 6, 2021

ABNORMAL FAN MOTOR 1) Turn off power supply. 2) Check fan motor wiring for any breakages, burn marks on the PC board, or moisture. If…

Non-Condensing Models

A.O. Smith 110-310-510 – ERROR CODE 510[510 (T-D2)], SIX FLASHES/51 [110 (T-KJR2), 310 (T-K4)] ABNORMAL GAS VALVES

Posted on December 6, 2021

ABNORMAL GAS VALVES Driving circuit fault for the main or solenoid gas valves. 1) If the hot water is shut off, but flames are still…

Non-Condensing Models

A.O. Smith 110-310-510 – ERROR CODE 441 [510 (T-D2)] FLOW SENSOR

Posted on December 6, 2021

Part of an Easy?Link system (510 (T?D2) only), the master unit signaled for an additional heater to activate and it did not. 1) Verify that…

Non-Condensing Models

A.O. Smith 110-310-510 – ERROR CODE 391 [510 (T-D2)], TWO FLASHES/39 [110 (T-KJR2), 310 (T-K4)] AIR?FUEL RATIO ROD FAILURE

Posted on December 6, 2021

1) Check that the wire connections are secure and free of burns or cuts. 2) Check that the clear plastic tube connecting the proportional gas…

Non-Condensing Models

A.O. Smith 110-310-510 – ERROR CODE 331 [510 (T-D2)] MIXING THERMISTOR

Posted on December 6, 2021

MIXING THERMISTOR 1) Check that the wire connections are secure and free of burns or cuts. The mixing thermistor is embedded in the water outlet…

Non-Condensing Models

A.O. Smith 110-310-510 – ERROR CODE 321 [510 (T-D2)], TWO FLASHES/32 [110 (T-KJR2), 310 (T-K4)] INLET THERMISTOR

Posted on December 6, 2021December 6, 2021

1) Check that the wire connections are secure and free of burns or cuts. The inlet thermistor is embedded in the water inlet connection. 2)…

Non-Condensing Models

A.O. Smith 110-310-510 – ERROR CODE 311 [510 (T-D2)], TWO FLASHES/31 [110 (T-KJR2), 310 (T-K4)] OUTPUT THERMISTOR

Posted on December 6, 2021December 6, 2021

OUTPUT THERMISTOR 1) Check that the wire connections are secure and free of burns or cuts. The output thermistor is located on the heat exchanger…

Non-Condensing Models

A.O. Smith 110-310-510 – ERROR CODE 121 [510 (T-D2)], THREE FLASHES/12 [110 (T-KJR2), 310 (T-K4)] FLAME LOSS

Posted on December 6, 2021December 6, 2021

FLAME LOSS This error code appears if the flames disappear while the unit is still supposed to be in operation. 1) Verify that the hi?limit…

Non-Condensing Models

A.O. Smith 110-310-510 – ERROR CODE 111 [510 (T-D2)], THREE FLASHES/11 (110 [T-KJR2), 310 (T-K4)] IGNITION FAILURE

Posted on December 6, 2021December 6, 2021

IGNITION FAILURE Heater does not fire after three failed attempts at ignition. 1) Verify that the hi?limit switch is not tripped. Turn the power off…

Posts navigation

Previous Page Page 1 … Page 4 Page 5 Page 6 Next Page

Pages

  • Contact Us

Recent Posts

  • How to Recalibrate a Thermostat
  • Solenoid Valves for Furnaces: A Basic Guide
  • Fuel Oil Burner Nozzles: What They Are and How They Work
  • Remote Bulb Temperature Control: A Basic Introduction
  • How to Clean Oil Burner Nozzle

Categories

  • A.O. Smith
  • Bradford White RG150T6N
  • Coal Firing
  • DIY
  • Gas and Oil Controls
  • Gas Burners
  • Honeywell Thermostat Manuals
  • Non-Condensing Models
  • Oil Burner
  • Steam and Hydronic Line
  • Thermostats and Humidistats
  • Troubleshooting
  • Valve
  • Wiring and Controls
© Copyright 2025 – Heater Service & Troubleshooting
Wisteria Theme by WPFriendship ⋅ Powered by WordPress

Terms and Conditions - Privacy Policy