A.O. Smith 110-310-510 – ERROR CODE 101[510 (T-D2)], FIVE FLASHES/10 [110 (T-KJR2), 310 (T-K4)] ABNORMAL COMBUSTION

Posted on December 6, 2021December 6, 2021

ABNORMAL COMBUSTION 1) Blockage in the airway. Check the following areas: a. Venting length obstruction (Birds’ nests, trash, etc.) b. Backflow preventer installed backwards c.…

Non-Condensing Models

A.O. Smith 110-310-510 – ERROR CODE 031 [510 (T-D2)], ONE FLASH/03 [110 (T-KJR2), 310 (T-K4)] INCORRECT DIPSWITCH SETTINGS

Posted on December 6, 2021December 6, 2021

INCORRECT DIPSWITCH SETTINGS 1) Turn off the power supply. 2) Remove front cover and locate the dipswitches on the center of the computer board. 3)…

Non-Condensing Models

A.O. Smith 110-310-510 – IT TAKES A LONG TIME TO GET HOT WATER AT THE FIXTURES

Posted on December 6, 2021

• The time it takes to deliver hot water to your fixtures depends on the length of piping between the two. The longer the distance…

Non-Condensing Models

A.O. Smith 110-310-510 – UNIT DOES NOT IGNITE WHEN WATER GOES THROUGH IT

Posted on December 6, 2021

Is the flow rate over 0.75 gpm? See if the unit initiates when you increase demand of water being drawn through the unit (e.g. opening…

Non-Condensing Models

A.O. Smith 110-310-510 – TEMPERATURE FLUCTUATES WHEN A FIXTURE IS OPENED

Posted on December 6, 2021

Make sure the unit is installed properly using the Proper Installation section (p. 6) of this guide. Check the flow and temperature right at the…

Non-Condensing Models

A.O. Smith 110-310-510 – THE WATER IS TOO HOT

Posted on December 6, 2021

The set temperature may be set too high. The temperature can be changed with dipswitches on the PCB or by the remote temperature controller, if…

Non-Condensing Models

A.O. Smith 110-310-510 – THE WATERIS NOT HOT ENOUGH

Posted on December 6, 2021

Compare the flow and temperature at the pressure relief valve. o If the temperature and flow rate are correct at the PRV then the problem…

Non-Condensing Models

A.O. Smith 110-310-510 – TROUBLESHOOTING

Posted on December 6, 2021

5.1 PRELIMINARY CHECKLIST Check all of these basic items before proceeding onto any other section: • GAS/WATER/ELECTRIC: o The gas supply valve should be fully…

Non-Condensing Models

A.O. Smith 110-310-510 – INSTALLATION

Posted on December 6, 2021

1. Follow all local codes, or in the absence of local codes, follow the most recent edition of the National Fuel Gas Code: ANSI Z223.1/NFPA…

Non-Condensing Models

A.O. Smith 110-310-510 – NORMAL OPERATION

Posted on December 6, 2021December 6, 2021

Becoming familiar with how a tankless water heater normally operates may help to figure out what is wrong with it. Assuming it is properly installed…

Posts navigation

Previous Page Page 1 … Page 5 Page 6

Pages

  • Contact Us

Recent Posts

  • How to Recalibrate a Thermostat
  • Solenoid Valves for Furnaces: A Basic Guide
  • Fuel Oil Burner Nozzles: What They Are and How They Work
  • Remote Bulb Temperature Control: A Basic Introduction
  • How to Clean Oil Burner Nozzle

Categories

  • A.O. Smith
  • Bradford White RG150T6N
  • Coal Firing
  • DIY
  • Gas and Oil Controls
  • Gas Burners
  • Honeywell Thermostat Manuals
  • Non-Condensing Models
  • Oil Burner
  • Steam and Hydronic Line
  • Thermostats and Humidistats
  • Troubleshooting
  • Valve
  • Wiring and Controls
© Copyright 2025 – Heater Service & Troubleshooting
Wisteria Theme by WPFriendship ⋅ Powered by WordPress

Terms and Conditions - Privacy Policy